Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Journal of Dental Anesthesia and Pain Medicine ; : 303-307, 2016.
Article in English | WPRIM | ID: wpr-124886

ABSTRACT

BACKGROUND: In dental intravenous sedation, continuous intravenous infusion of a low-dose drug requires an infusion pump such as a syringe pump. To develop a new syringe pump for clinical use, the functions of the pump must meet certain international standards. Various safety and efficacy tests must be performed on the syringe pump, as stipulated by these standards, and an approval must be received from the approving agency based on such test results. METHODS: The authors of the present study developed a novel syringe pump and performed efficacy evaluation by testing its infusion speed at 1 and 25 ml/h, and infusion performance testing at 2 and 24 h. Moreover, performance evaluation was conducted by comparing the novel pump to an existing pump with the infusion speed varied from 1 to 5 ml/h. RESULTS: In the efficacy testing on the newly developed syringe pump, infusion with the infusion speed initially set to 1 ml/h resulted in infusion speeds of 1.00 and 0.99 ml/h in the 2- and 24-h assessment, respectively. Changing the infusion speed setting to 25 ml/h resulted in an infusion speed of 25.09 and 23.92 ml/h in the 2- and 24-h assessment, respectively. These results show no significant differences when compared with other commercially available pumps. CONCLUSIONS: The efficacy testing of the newly developed syringe pump showed the accuracy to be within tolerance. Based on these findings, we believe that the newly developed syringe pump is suitable for clinical use.


Subject(s)
Data Accuracy , Infusion Pumps , Infusions, Intravenous , Syringes
2.
Journal of Dental Anesthesia and Pain Medicine ; : 5-10, 2015.
Article in English | WPRIM | ID: wpr-95441

ABSTRACT

BACKGROUND: Patients were subjected to post-discharge follow-up (by telephone) in order to investigate the potential complications of outpatient general anesthesia or deep sedation that could develop in disabled dental patients discharged from the hospital. The ultimate aim of this study was to establish an appropriate response measure for such complications. METHODS: The caregivers of 79 disabled patients who underwent dental procedures under general anesthesia at our outpatient clinic were interviewed over telephone. Necessary care instructions were provided during the phone calls when required. The patient satisfaction level regarding the telephonic follow-up care was surveyed by additional telephone calls. RESULTS: Most of the patients did not suffer any serious complications; however, some reported fever and bleeding. The data obtained in this study can be utilized towards the development of caregiver education pertaining to the ambulatory general anesthesia of dental patients with disabilities. CONCLUSIONS: Additionally, we hope that the findings of this study will help minimize the effects of complications experienced by disabled dental patients undergoing ambulatory general anesthesia, as well as increase the overall patient satisfaction level.


Subject(s)
Humans , Ambulatory Care Facilities , Anesthesia, General , Caregivers , Deep Sedation , Education , Fever , Follow-Up Studies , Hemorrhage , Hope , Outpatients , Patient Satisfaction , Telephone
SELECTION OF CITATIONS
SEARCH DETAIL